Compression set testing for Australian seal buyers: what belongs on the order

Advertisement

To compare two elastomer batches, order one agreed compression-set protocol covering specimen preparation, exposure, recovery measurements and reporting for both batches.

From above of arranged rows of trial spectacle lenses for examining visual impairments in clinic
  • Essential comparison controls: agree the method edition, specimen route, test conditions, recovery plan, replicate reporting and purchase-specification acceptance criterion before testing.
  • Optional additions: specify supplementary tests or extra recovery observations separately, unless your purchase specification requires them.

These are order-writing controls, not a statement of universal ASTM requirements. Use the laboratory’s accredited scope as the starting point, then agree the details needed for the comparison.

Advertisement

Check the accredited scope

NATA lists Central Laboratory in Dandenong South, Victoria, under accreditation no. 1279, site no. 1272, as accredited to ISO/IEC 17025 (2017) for specified testing activities. Its compression-set entry names ASTM D395 (Method B), “compression set under constant deflection in air” and “prepared test specimens”. [1]

The cited scope does not establish intact-seal eligibility, an ASTM edition year or the detailed preparation, exposure and recovery protocol. [1] Confirm those details for the proposed work rather than treating the entry as blanket coverage.

No limitation or range appears in the compression-set row, but NATA says its display contains only information considered necessary to describe accredited activities. Verify the applicable scope when ordering. Services are “conditionally available to external clients”, so confirm the laboratory can accept the work as specified. [1]

Advertisement

Agree finished seals versus prepared specimens

Before dispatch, agree what will go into the fixture. The documented category, “prepared test specimens”, does not establish whether specimens may be cut from finished seals, must be separately moulded or whether seals can be tested intact. [1]

Put these routes to the laboratory as options to resolve, not confirmed capabilities:

  • Intact finished seals: submit the seal without cutting a specimen from it.
  • Specimens from finished parts: supply seals from which test specimens would be prepared.
  • Separately moulded test pieces: supply pieces made for testing rather than taken from finished seals.

Ask the laboratory to check the proposed route against the agreed method edition. Record:

  • Source: the specimen route for each batch.
  • Geometry: the agreed shape and dimensions.
  • Responsibility: whether the supplier, purchaser or laboratory prepares the specimens.
  • Procedure: the common preparation instruction for both batches.
  • Departures: any unavoidable differences in preparation.

If a common route cannot be agreed, resolve the comparison design before proceeding. Do not treat unlike specimens as a straightforward batch comparison.

Advertisement

Lock the edition and exposure into one protocol

Complete the protocol for both batches before authorising testing. Matching is a purchasing control here—not a claim that every setting is prescribed by the method.

The documented activity is ASTM D395 Method B, constant deflection in air; the cited scope does not supply the edition, preconditioning, deflection percentage, exposure temperature or duration. [1] For each field below, record Batch A / Batch B / agreed basis or permitted departure:

  • Method and edition: the full designation and agreed edition, with departures identified.
  • Specimen specification: source, preparation route and dimensions, referencing the common preparation instruction.
  • Preconditioning: conditions and duration, with the protocol provision being followed.
  • Constant-deflection setting: the setting and its agreed basis.
  • Environment: air when ordering the documented scope activity; flag an alternative for separate scope confirmation. [1]
  • Exposure temperature: the temperature for each batch.
  • Exposure duration: the duration for each batch.

Have the laboratory check these entries against the agreed standard edition and purchase specification. Do not let a blank field mean “use whichever conditions accompanied the supplier’s previous result”.

If supplier percentages have different preparation, exposure or recovery entries, reconcile those differences before treating them as a controlled batch comparison. Record intended service conditions separately as context for choosing the protocol.

Advertisement

Specify recovery measurements and replicate results

Permanent set is deformation remaining after load removal, as described in AdvanSES’s elastomer-mechanics article. This is background from an India-based laboratory, not an Australian testing option. [3] Recovery therefore needs an explicit place in the order rather than an unexplained percentage in the report.

Ask the laboratory to complete and agree these entries for both batches:

  • Recovery interval: the agreed interval and the event from which the clock starts.
  • Recovery conditions: the atmosphere and other agreed conditions, using the same protocol for both batches.
  • Measurement schedule: when each reading is taken; identify any optional additional observations separately.
  • Readings and calculation: the applicable initial and post-recovery measurements, units and calculation under the agreed edition. Do not prescribe an assumed sequence.
  • Replicates: specimen count per batch, individual specimen results and the agreed summary statistic.
  • Exceptions: how unusable specimens, exclusions, replacements and protocol departures will be recorded and handled in the summary.

NATA’s scope, the DMA guide and the AdvanSES background do not establish a compression-set recovery interval, measurement schedule, calculation procedure, replicate minimum or whether average-only reporting is sufficient. [1][2][3] Resolve these entries against the agreed standard edition before testing.

Advertisement

Build sample IDs and issue the order

Give each specimen a unique label and keep a key linking it to the original supplier batch identifier, even if the laboratory receives blind labels. Use the register as an organisational tool, not a laboratory-mandated form.

Illustrative ID pattern: SUB-A-01 identifies a specimen from Batch A; SUB-B-01 identifies a specimen from Batch B. Keep the supplier and original lot details in the corresponding register entries.

Include these fields for every specimen:

  • Internal or blind specimen ID, supplier and original batch or lot identifier.
  • Material designation and source item, such as the identified seal or moulded test piece.
  • Preparation route and responsibility.
  • Known prior exposure or conditioning; mark unknown history explicitly.
Advertisement

Before issuing the order, attach and cross-reference:

  • The purchase-specification reference and revision, including the acceptance criterion.
  • The agreed method edition and specimen-preparation instruction.
  • The matched exposure protocol.
  • The recovery measurement and replicate plans.
  • The reporting fields: specimen IDs, individual results, summary, conditions and recovery measurements.
  • Instructions to flag proposed departures before testing and identify actual departures in the report.

Suggested order wording:

Compare Batch A [original identifier] and Batch B [original identifier] under attached protocol [reference/revision], using sample register [reference]. Apply the agreed specimen preparation, exposure, recovery and replicate plans to both batches. Report specimen-level results and the agreed summary. Notify us of proposed departures before proceeding, and identify actual departures separately in the report.

Advertisement

Check the report before accepting material

Check the report against the order and sample register, not just the headline percentages:

  • Laboratory and method: laboratory name, testing site, method and edition match the order.
  • Traceability: specimen IDs link to the correct batches.
  • Preparation: specimen source, dimensions and preparation match the protocol.
  • Exposure: deflection, medium, temperature and duration are recorded for both batches.
  • Recovery: conditions, measurement timings and agreed initial and post-recovery readings are included.
  • Results: individual values, the agreed summary and protocol departures are identified.

Resolve missing or inconsistent entries with the laboratory before using the results to accept material. Request a corrected report or written clarification where needed.

Advertisement

Keep the decisions separate: does the report represent the agreed comparison? Then, does each batch meet the purchase specification? If acceptance limits or the decision rule are absent, agree them before labelling either batch pass or fail.

The cited pages provide no universal acceptance threshold, prescribed reporting format, compression-set uncertainty figure or validated conversion from one percentage to field seal life. [1][2][3]

Record the decision against explicit references:

Report [reference] represents the comparison under [protocol/revision and conditions]. Batch [identifier] is assessed as [accepted/not accepted/decision deferred] against purchase specification clause [reference], using decision rule [reference]. Outstanding issues: [details or none].

Advertisement

Keep supplementary tests separate

Specify supplementary tests only to answer a separate purchasing question, or where the purchase specification requires them. Central Laboratory’s scope also lists hardness, tensile properties, swelling in liquids and accelerated ageing under specified methods; check proposed supplementary work against the relevant entry. [1]

Do not substitute a different measurement for the ordered compression-set result:

  • DMA applies sinusoidal excitation at controlled amplitude and frequency, recording force and displacement. It is not the documented ASTM D395 compression-set procedure. [1][2]
  • Stress relaxation concerns force decreasing while deformation is held constant, rather than deformation remaining after unloading. [3]

Label these results as supplementary evidence rather than merging them into the compression-set comparison. Keep DMA-specific frequency controls, dimensional-error figures and modulus claims out of the compression-set checklist. [1][2][3]

References

  1. Central Laboratory – Accredited Organisation (Site No. 1272) – NATA (nata.com.au, 2023)
  2. DMA Testing for Rubber and Elastomers: Complete Guide (google.com)
  3. Deformation Mechanisms in Elastomers – Rubbers – AdvanSES (google.com, 2020)