HROUS

Commercial glasswashers: requirements for Australian cafés

Advertisement

To choose an underbench commercial glasswasher, verify tallest-glass fit, usable rack capacity, installed space, services and peak-service turnaround—not rack footprint alone. HOBART’s G415 specification sheet and AGC Equipment’s undated G400 brochure do not publish glasses-per-rack capacities. [1][2]

Advertisement
A collection of upside-down glasses drying on a stainless steel rack with soft lighting.
  • Essential checks: demonstrate glass fit, verify usable rack loading, test turnaround with handling time, and confirm space, power, water and drainage.
  • Conditional requirements: assess water treatment and any additional connections against the selected machine’s operating conditions.
  • Optional equipment: the G415 sheet lists an alternative-rack grid insert and reverse-osmosis units as options; keep these separate from standard inclusions. [1]
Advertisement

Start with your tallest glass

Measure the tallest drinkware’s overall height, widest diameter, base or stem shape, and intended loading position. Give these measurements to the supplier, ideally with representative glasses for a loading demonstration.

Keep three measurements separate:

  • Rack footprint: the rack’s outside length and width.
  • Glass position: how each glass sits in the selected rack, including its angle and spacing.
  • Usable glass height: the clearance available for the glass in that position inside the machine.

The G415 sheet specifies one supplied 396 × 396 mm rack with four sloped rows. [1] The G400 brochure specifies a 400 × 400 mm rack. [2] Do not treat similar footprints as proof of interchangeability or equal capacity.

The G415 sheet lists a loading height of 315 mm, while the G400 brochure lists an input height of 343 mm. [1][2] Use these published figures for an initial comparison, not as proof that your tallest glass fits in the chosen loading position. Confirm usable clearance and loading arrangement with the supplier, or arrange a demonstration with the selected rack and representative tallest glasses. Verify the usable glass count at the same time for the peak-demand calculation.

Advertisement

Turn peak demand into required rack loads

Choose a defined peak-service window, record its duration and count the glasses needing washing within it. Use that count—not the café’s total glass stock—as the demand input.

For the loading check, use the expected drinkware mix rather than identical small glasses. Record the usable count for the selected rack and loading arrangement.

Required rack loads = peak glasses ÷ verified usable glasses per rack, rounded up to a whole rack load.

If tall drinkware and smaller water glasses need separate loading arrangements, divide each group’s glass count by its verified rack capacity, round each result up, then add the loads. If testing a representative mixed load, use that mixed-load capacity.

Peak-demand worksheet

  • Record the peak window’s start and end times and its duration in minutes.
  • Record the number of glasses requiring washing during that window.
  • Record the drinkware mix or separate loading group.
  • Record the verified usable glasses per rack.
  • Calculate required rack loads by dividing the glass count by the verified usable glasses per rack and rounding up.

Repeat for separate groups where needed. The total is the workload to test against realistic turnaround.

Advertisement

Test turnaround with handling time included

The published rates describe different programme offerings:

  • G415: programmes of 60, 90 and 180 seconds, with nominal capacity up to 60 racks per hour on the shortest programme. [1]
  • G400: one programme and a theoretical capacity of 30 racks per hour. [2] Ask for the programme duration. Do not infer an exact cycle time from that rate.

The G415’s Thermostop qualification matters: with cold-water and/or 240 V connection, actual cycles extend to achieve the required temperatures. The shortest published programme is therefore not a guaranteed elapsed time under every installation condition. [1]

Request a timed demonstration under the proposed operating conditions, using the intended drinkware, verified loading and realistic staff workflow. Record programme time and handling time separately, then complete this sequential planning check:

Advertisement
  • Elapsed time per load: add observed programme time to non-overlapping loading, unloading and changeover time, and record the result.
  • Planning time: multiply required rack loads by measured elapsed time per load, and record the result.
  • Peak-window check: compare planning time with the recorded service window, using the same units.

If staff load another rack while the machine runs, time the repeated end-to-end workflow instead; do not count overlapping tasks twice. Include handling needed to make the final load’s glasses available for service.

Illustrative example: 60 glasses at a verified 18 per rack need four loads. A demonstrated end-to-end time of 2 minutes 10 seconds per load gives 8 minutes 40 seconds for four loads. That workflow would miss an 8-minute peak window. Use your own glasses, rack and staff timing for the decision.

If the workflow misses the peak window, reassess rack loading, staff workflow or machine choice rather than relying on the headline rack rate.

Advertisement

Check the complete underbench space

Measure the opening’s height, width and depth. Record separate space for door movement, connections and service access; do not use cabinet dimensions as the entire installation envelope.

  • G400: published cabinet dimensions are 790 mm high × 450 mm wide × 517 mm deep. Request the installed height with the proposed feet or supports. [2]
  • G415: the manufacturer’s drawing shows a cabinet 700 mm high × 460 mm wide × 590 mm deep, with 150 mm adjustable legs shown separately. The drawing shows 940 mm from the rear of the unit to the edge of the open door. Confirm the proposed installed height and service clearances. [1]

Use the G415 drawing to check the doorway and bench opening. Obtain the service clearances for both machines and the G400 door-swing and support details before the installer signs off. [1][2]

Obtain a model-specific installation drawing and have the supplier check the proposed configuration against the measured space. Do not calculate total G415 installed height from the leg figure alone. Include hose routing and access to cleaning components in the check.

Advertisement

Verify power, water and drainage

Have qualified plumbing and electrical trades assess the proposed connections and any required work before ordering. Use the specifications below alongside the model’s installation instructions.

HOBART ECOMAXPLUS G415

  • Power: total standard loading is 2.8 kW at 15 A, with an electrical cable and plug included. Have the electrician check compatibility with the intended supply. [1]
  • Water: maximum inlet-water temperature is 60°C, reduced to 35°C when using reverse osmosis. Supplied connection equipment includes fill and drain hoses, a rinse pump, a drain pump and a backflow preventer identified as WaterMark approved. [1]
  • Drainage: the drain hose is 2,000 mm long, with ID20/OD25 dimensions. Have the plumber assess the hose and proposed waste route. [1]
Advertisement

G400

  • Power: the brochure specifies 240 V single-phase supply and a 15 A fuse rating. Have the electrician check the proposed connection. [2]
  • Water: maximum inlet-water temperature is 55°C. [2]
  • Connection details: obtain drainage arrangements, inlet-pressure requirements, hose and cable lengths, and plug type before the trades assess compatibility. [2]

The G415 sheet identifies an independent gravity waste to a tundish for the optional RO-IV/RO-S arrangement. If selecting that equipment, have the plumber assess this additional route separately from the glasswasher’s drain connection. [1]

Separate operating conditions from optional equipment

For machine protection, the G415 sheet says water hardness should not exceed 3°dH. Above that level, it recommends an integrated softener or an external HYDROLINE PROTECT softener. Check water hardness before deciding on treatment. [1]

Advertisement
  • Standard inclusions: alongside the connection equipment above, the G415 sheet lists detergent and rinse-aid dispensers as supplied. [1]
  • Optional rack equipment: a stainless-steel grid insert for accepting other racks is an option. Verify the chosen rack’s loading arrangement separately. [1]
  • Optional reverse osmosis: free-standing RO-IV or RO-S units are offered for what HOBART calls “polish free washing”—a vendor claim, not an independently established result. The lower inlet-temperature limit and separate waste arrangement apply when selecting the optional RO equipment. [1]

Request model-specific accessory and water-treatment guidance for the G400 rather than applying the G415’s hardness recommendation or options to it. [2]

Check rack inclusions, access and handover

The G415 sheet lists one glass rack as supplied equipment. [1] Ask whether a rack is included with the G400 and in what quantity, and confirm installation and handover coverage for either model. [1][2]

For routine cleaning access, the G415 sheet lists a removable tank strainer, coarse filter and pump-suction casing, plus integrated self-cleaning during drain-out. Ask for a demonstration in the proposed installation. [1]

Before ordering, request a written supply and handover checklist:

  • Identify supplied racks, configurations and quantities, including agreed extras.
  • Itemise connection equipment and obtain installation instructions.
  • Record agreed commissioning and handover tasks and who will perform them.
  • Arrange a demonstration of drinkware loading, operation, drain-out and routine cleaning access.

Keep these agreed tasks with the order rather than assuming they are included in either equipment package.

Make the final selection

Mark each essential check confirmed, unresolved or does not meet requirement, with its supporting measurement or demonstration result:

  • Tallest drinkware fits in the selected rack.
  • Usable glasses per rack have been verified.
  • Required loads clear the peak window with handling time included.
  • The installed machine allows door movement, connections and service access.
  • Qualified trades have assessed power, water and drainage compatibility.
  • Racks, necessary treatment and handover tasks are itemised.

Resolve critical gaps before ordering and request specifications matching the exact proposed unit. Use the published height figures as a starting point; final selection still depends on verified drinkware fit, rack loading and peak-service turnaround, rather than either model sheet alone. [1][2]

References

  1. ECOMAXPLUS G415 GLASSWASHER (hobartfood.com.au, 2020)
  2. G400 Undercounter (agcequipment.com.au)
Advertisement