How to Choose Surface Roughness Testing for Canadian Buyers
Start with a reusable inspection request
To choose surface roughness testing, ask the laboratory to confirm the drawing requirement, measurement conditions and report deliverables in writing. Matching Ra values alone do not establish comparable requirements when cutoff or surface direction differs. [5][6]

Separate the drawing’s acceptance requirements from measurement details needing laboratory agreement. Use this checklist as a request template, not a standard-mandated form:
- Part identification: Record the part number and revision, and attach the controlled drawing. [6]
- Controlled surface: Identify the face or zone and attach a marked drawing. [6]
- Acceptance requirement: Record the parameter, drawing limit, unit, and governing standard and edition. [5][6]
- Measurement method: Ask for the proposed method and instrument, and confirmation of suitability for the specified features. [3][6]
- Measurement settings: Ask for the cutoff/sampling length, filter, total evaluation coverage and proposed defaults.
- Sampling plan: Agree on the parts to inspect, measurement sites, repeats per site and traverse direction relative to lay. [5][6]
- Surface state: Record the manufacturing stage, material and condition, incoming surface condition and handling requirements. [6]
- Report: Request part/revision and site identification, individual values and units, agreed method and settings, surface condition and acceptance status. [3][6]
This guide concerns measurement of machined surfaces—not blast profile, instrument calibration services or buying a tester.
Keep the drawing’s parameter and unit
In technical background from Shenzhen, China-based machining business CHX, Ra is the arithmetic mean deviation of the roughness profile from its mean line over a sampling length. As an average, it can hide isolated peaks and scratches. Rz describes peak-to-valley behaviour, which can matter on features such as sealing faces. CHX is a machining provider, not a Canadian testing option. [5]
Retain the specified parameter and unit in both the request and report. MakeNexa’s engineering guide cautions that Ra and Rz have no exact conversion: their relationship depends on the process, material, profile, cutoff and measurement method. Do not replace the drawing requirement with a multiplier. [6]
If a supplier reports Ra when the drawing specifies Rz, request the specified measurement rather than treating the reported value as equivalent. Keep the same discipline when checking units.
Resolve the governing standard before booking
Copy the drawing’s standard reference and edition into the request. B46.1 is published by ASME: its title is Surface Texture (Surface Roughness, Waviness, and Lay). Use the correct publisher and complete designation, such as ASME B46.1-2019 when that edition is required.[7]
CMH’s mechanical-testing page labels its roughness reference “ASTM B46.1”.[1] Treat that as a reference requiring correction in the proposed quotation, rather than as another valid name for ASME B46.1. Ask the laboratory to identify the actual document, edition and method it will use.[7]
CMH’s surface-inspection page also lists ISO 4288 / DIN references.[3] The document governing the job must follow the controlled drawing and contract. Record the parameter definition, units and treatment of unspecified measurement settings. If the laboratory proposes a different standard or edition, obtain written approval from the party controlling the requirement before testing, and retain that decision with the request.
Check the method against the specified features
Send the controlled drawing and ask the laboratory to confirm that its method can measure the specified features—not simply that it offers roughness testing.
For example, CMH describes contact profilometry using a diamond or sapphire tip traversing the surface and names Ra, Rz and Rt among its parameters. [1] Ask whether the proposed method suits the geometry and marked measurement sites.
Integrity Testing Laboratory in Markham, Ontario lists surface-roughness testing, a surface roughness tester and an optical interferometer/profilometer. It offers testing to applicable specifications or client requirements. [2] Ask which instrument and method it proposes for the component; an equipment list is not a job-specific commitment.
Ask CMH or ITL to confirm feature-specific access and operating limits for the submitted component. [1][2] Request a capability response covering:
- The method and instrument proposed for each feature.
- Which faces and sites can be measured.
- Geometry-related restrictions on measurement coverage.
- Any alternative method, with approval required before substitution.
Agree on filtering, cutoff and evaluation coverage
CHX explains that changing cutoff can change the reported number without changing the part. [5] MakeNexa likewise cautions that identical Ra callouts with different cutoffs are not equivalent; an unspecified cutoff can lead to a supplier default differing from the buyer’s inspection method. [6]
YISHUN, a Shenzhen, China-based machining and metrology-planning provider included as background only, not a Canadian testing option, recommends stating cutoff length, filter and sampling length, along with the method, instrument and conditions. [4]
Ask the laboratory to record these separately:
- Filter: the specification and settings proposed.
- Cutoff and sampling length: the selected values and terminology used by the procedure.
- Total evaluation length: the coverage evaluated for each result.
- Defaults: settings proposed where the drawing is silent, for approval before testing.
Ask the laboratory to propose the number of sampling lengths and total evaluation length under the agreed procedure rather than inserting a blanket setting. [6]
If reports identify the same face and parameter but omit—or differ in—cutoff, obtain the settings before treating the discrepancy as evidence of a changed finish. [5][6]
Mark sites and traverse direction
Attach an annotated drawing or photograph identifying controlled faces, labelled measurement sites and intended traverse paths. Identify functional zones such as sealing lands and bearing seats using the drawing’s acceptance requirements, without assigning new limits. [6]
Keep surface lay and instrument travel separate. CHX explains that Ra alone does not describe direction: surfaces with the same Ra can behave differently when their lay differs. [5] MakeNexa identifies drawing symbols for lay, including parallel, perpendicular, circular and radial patterns. [6]
Preserve the drawing’s lay requirement and separately ask the laboratory to mark its traverse direction relative to that lay. Agree on a part-specific plan rather than applying an unsupported blanket traverse rule.
Confirm the number of parts, sites per part and repeats at each site. Request the same part and site identifiers in the report so individual results map back to the agreed measurement locations.
Confirm access, fixturing and surface condition
Highlight bores, recesses, edges, threads and other constrained features for an access review. MakeNexa’s geometry guidance identifies these as areas to address when planning coverage. [6] Ask for the proposed fixturing approach and a list of sites that cannot be measured as requested.
Define the condition being accepted: base material, grade, material condition, incoming surface state and manufacturing stage. MakeNexa’s request guidance calls for material condition, final-dimensional state and inspection requirements. [6] State whether measurement is required before or after the specified finishing operation.
Ask whether cleaning or other preparation is proposed, and require approval before changing the agreed surface condition. Include handling and packaging instructions in the request; MakeNexa includes these among the details defining the condition being accepted. [6]
Specify the report and traceability evidence
Carry the agreed conditions into the report specification. Request these as job-specific deliverables rather than assuming they belong to the laboratory’s standard package:
- Requirement identity: part number, revision, controlled drawing, face and site identifiers, parameter, unit, standard and edition. [5][6]
- Measurement setup: method, instrument, filter, cutoff, sampling length, evaluation coverage and traverse direction. [4][5][6]
- Condition and results: manufacturing stage, surface condition, individual values with units, sample coverage and acceptance status against the drawing requirement. [3][5][6]
CMH expressly lists recommendations, pass/fail status and standard compliance among its inspection-report contents. [3]
Ask CMH or ITL to confirm the report contents and available traceability evidence in writing. [1][2][3]
Request a sample report or written deliverables list. Separately ask for instrument identification and calibration-traceability evidence, plus an uncertainty statement or raw profile traces where needed. Agree how pass/fail will be assigned against the drawing requirement, rather than relying on a standard-compliance statement alone.
Get the scope and price in writing
Attach the drawing and completed checklist to the quotation request:
Please quote against the attached revision-controlled drawing and inspection checklist. Confirm the requested scope and report deliverables, and identify exclusions or proposed deviations before authorisation.
Ask for written answers to these commercial questions:
- What is the itemised price basis for parts, sites, repeats, setup and reporting? How is preparation or additional work priced?
- What turnaround is committed, and when does it start?
- Who arranges shipping or on-site access?
- Whose approval is needed before additional work proceeds?
- What cancellation terms and retest charges apply?
Ask CMH or ITL to include prices, cancellation terms and a committed turnaround in the written quote. [1][2][3]
Before authorising testing, confirm the requirement, feature access, settings, coverage, report, traceability evidence, cost and timing.
If reports conflict, reconcile part revision, parameter, unit, standard, settings, evaluation coverage, sites, direction and surface condition before commissioning another test. Cutoff alone can affect the result without a change to the part. [5][6] Then send the supplier and laboratory one agreed remeasurement scope, with any retest charge settled beforehand.
References
- Mechanical Testing Services | CMH Metlabs (cmhmetlabs.ca)
- Mechanical and Physical Testing – ITL Inc (itlinc.com)
- Surface Inspection Services Canada | CMH Metlabs (cmhmetlabs.ca)
- How Surface Finish Affects Ultra Precision Machined Parts – YISHUN Optical (yishunoptical.com)
- Surface Finish on CNC Parts: What Ra Actually Measures, and How to Specify It Without Overpaying – DEV Community (dev.to)
- Surface Finish Chart: Ra, Rz, RMS and Callout Symbols | MakeNexa (makenexa.com, 2026)
- ASME B46.1-2019 — Surface Texture (official title and contents) (asme.org, 2020)