How to choose analytical balance calibration for Quebec labs
Choose analytical balance calibration by agreeing the place of use, working range and report before booking. Ask the provider to distinguish measurement, any authorised adjustment and the evidence used to decide whether the balance meets your laboratory’s needs. These are purchasing and quality-control questions, not a universal Canadian legal checklist.

Define the weighing task before comparing quotes
Send every provider the same instrument and application details:
- Instrument: manufacturer, model, serial number, instrument ID, maximum capacity and display interval.
- Use: laboratory address, smallest routine net sample, usual tare vessels and highest working load.
- Acceptance: allowable weighing error, relevant procedure or standard, and any accreditation or reporting requirement.
Request identified test loads, repetitions and range coverage. In Sartorius’s EURAMET cg-18 certificate explanation, repeatability is reported as a standard deviation; eccentricity measures the effect of load position; indication-error results compare the reading with the reference value. The certificate can cover a restricted range, so the balance’s maximum capacity is not proof that every range was calibrated.[3]
Ask the provider to explain how the proposed test plan addresses your smallest sample as well as the upper working load. Do not impose an arbitrary set of quarter-capacity points or a fixed repetition count without checking the selected procedure and application.
Preserve the condition found before adjustment
Sartorius’s certificate guide describes an initial measurement before maintenance or adjustment followed by an independent set of measurements afterward.[3] Ask the provider to label these results clearly as “as found” and “as left” and keep both sets of evidence.
Put that sequence in the order: complete and retain the agreed as-found measurements first; obtain written authorisation for adjustment or repair; then repeat the relevant measurements and report as-left results. Record what changed. Agree how automatic internal adjustment will be handled so the initial condition is not lost.
Ask for the external reference-weight evidence rather than accepting a built-in adjustment routine as the whole calibration service. Specify a separate approval contact and spending limit for repair. If a failed result might affect earlier laboratory work, send the as-found evidence to the responsible quality manager for assessment.
Calculate minimum sample mass using the applicable criterion
Readability is not minimum usable net sample mass. Sartorius’s April 2026 white paper explains a pharmacopoeial repeatability criterion of 2s/m ≤ 0.10%, with s replaced by 0.41d when smaller; d is the display interval. The corresponding theoretical minimum is m = 2,000 × max(s, 0.41d). This example applies only where that method is required; it is not a blanket Canadian laboratory rule.[2]
Illustrative calculation: if d = 0.1mg and measured s = 0.05mg, the floor is 0.041mg and the effective s remains 0.05mg. The calculated minimum is 2,000 × 0.05mg = 100mg. Multiplying s by two alone would omit the relative-error denominator.[2]
The uncertainty coverage factor and an additional process safety factor have different roles. Sartorius discusses a safety margin between a chosen smallest net sample and the calculated minimum; it is not a substitute for the acceptance criterion. Confirm the method, units and margin with the provider. A heavy tare does not make an undersized net sample acceptable.[2]
Ask the provider to name the assessment method and tolerance used for your weighing procedure, and to explain how the reported uncertainty affects the laboratory’s decision about usable loads.
Check on-site service and accreditation coverage
Quebec example: Covariance, based in Sainte-Thérèse, advertises analytical-balance calibration and repair with standard-method, USP and ISO 17025:2017 options. Its cited service page does not establish the exact on-site territory, accreditation scope or certificate package.[1] Obtain a written quote for the named laboratory address.
Request the issuing laboratory’s legal name, accreditation certificate and scope, and ask which entries cover the proposed activities, range and uncertainty. An advertised ISO reference is not enough to answer those job-specific questions.
Ask for reference-weight identification, certificate references and the basis for treating the weights as suitable on the visit date. Agree the recalibration and checking arrangements using the laboratory’s procedure, use history and stability evidence. Do not assume one universal one-to-three-year interval for every weight set.
Prepare the site and agree the report
Request a pre-visit checklist for the exact balance: installation and levelling, warm-up, pan and chamber condition, environmental stability and control of drafts or vibration. Assign who prepares the instrument and who decides whether unsuitable conditions require correction or rescheduling.
Sartorius’s certificate guide includes instrument identification, calibration location, measuring conditions, reference equipment, results and uncertainties. It also distinguishes calibration uncertainty from uncertainty during normal use.[3] Ask the quotation to commit to the following deliverables:
- Instrument and location identifiers, calibration date, method and measured range.
- Test loads, results and units for the agreed repeatability, eccentricity and indication-error tests.
- As-found results, any authorised changes and corresponding as-left results.
- Reference-weight records, traceability evidence, measurement uncertainty and coverage factor.
- The minimum-sample assessment where ordered, including the criterion, calculation and stated limitations.
If you need a pass/fail statement, provide the acceptance limits and agree the decision rule, including treatment of uncertainty, before testing. Request a corrected report when an agreed deliverable is absent; a calibration label alone does not answer the scope questions.
Settle price, timing and change approval
Get an itemised total covering the visit, travel, tests, certificate, any minimum-sample assessment, adjustment and repeat testing, including applicable taxes. Ask which work is included and which needs separate authorisation. Confirm downtime, report turnaround, cancellation terms and service-warranty terms in writing.
Use this request with the instrument details:
Please quote for on-site analytical balance calibration at [address]. Our working range is [range], smallest net sample is [mass], tare loads are [loads] and acceptance requirements are [procedure and limits]. Propose test loads and repetitions, preserve as-found evidence before changes, and report any as-left testing. Confirm accreditation coverage, traceability, uncertainty, minimum-sample assessment, deliverables, total price and change-authorisation terms.
Compare the written responses against that same scope. Choose the service that supplies usable evidence for the laboratory’s actual weighing tasks and a clear route for resolving failures.
References
- Balances | Covariance (covlab.ca)
- Sartorius — Minimum Sample Weights (April 2026) (sartorius.com)
- Sartorius — EURAMET cg-18 calibration certificate explained (March 2022) (sartorius.com)