Charpy Impact Testing for Australian Steel Buyers: Requirements
For a Charpy impact-testing request, separate specification-controlled requirements—method, specimen details, temperature and required measurements—from optional outputs and suggested traceability fields, then check the selected laboratory site’s NATA scope.[2][3][4][5]

- Specification-controlled: identify the governing purchase specification, material standard or welding code, its acceptance criteria, and the required specimen and test conditions.[2]
- Suggested traceability: link the submitted material and samples to the order using agreed identifiers; these are not universal report requirements established by the cited pages.
- Additional outputs: treat lateral expansion or fracture-surface measurements as required when the specification calls for them; otherwise identify them as optional requests and check scope coverage.[2][3][4][5]
Start with the purchase specification and material identity
LMATS says the material standard or welding code controls notch type, location and orientation, while absorbed energy is compared with the applicable compliance criteria.[2]
State whether the submitted material is parent metal or a welded test piece so the work can be matched to the relevant accredited specimen category.[3][4][5]
For traceability, consider including the purchase-order reference, specification revision, steel grade, heat or cast identifier, product form and sample identifier. Treat these as suggested linking fields, not a prescribed laboratory form.
Resolve the intended method designation before issuing the request. LMATS’s service page uses AS/NZS 1544.2 and ISO 148.1, whereas its Melbourne and Sydney NATA scopes use AS 1544.2 and ISO 148-1.[2][3][4] Agree the designation against the governing specification rather than silently substituting the service-page wording.
Agree specimen orientation, dimensions and temperature
Record the required extraction location, specimen orientation and notch orientation against the governing specification, using an agreed drawing or clearly defined notation where useful. LMATS attributes notch type, location and orientation to the material standard or welding code; leave extraction and testing procedures to the appointed professionals.[2]
Keep these details separate in the request:
- Location and orientation: identify where the specimen is to come from and how the specimen and notch are to be orientated under the applicable specification.[2]
- Overall specimen dimensions: LMATS describes the standard Charpy specimen as a 55 × 10 × 10 mm bar.[2] Treat this as a reference size, not an instruction for every order: confirm the required dimensions and any sub-size provisions against the governing specification before preparation.
- Notch geometry: LMATS’s published V-notch geometry is a 2 mm depth, 45° angle and 0.25 mm root radius; these describe the notch, not the specimen’s overall dimensions.[2]
- Test temperature: retain the temperature required by the purchase specification and check it against the selected site’s scope.[3][4][5]
The cited service and scope pages do not establish universal specimen counts, retest rules, averaging requirements or minimum individual energy values.[2][3][4][5] Take those instructions from the applicable specification and resolve their application with the appointed professionals rather than inserting defaults.
Mark unresolved dimensions, sampling details or orientation as open items in the draft request. Assign responsibility for resolving them before specimen preparation. This is an ordering safeguard, not a published accreditation rule.
Check the exact laboratory site’s NATA scope
Match the specimen category, method, temperature and requested measurements to the specific laboratory site. LMATS’s general service page describes provider-wide capabilities; it and the Melbourne listing refer to the same business, not independent providers.[2][3]
- LMATS Melbourne — Site 17127, Victoria: covers prepared metallic and welded specimens under AS 1544.2, AS 2205.7.1, ASTM E23 and ISO 148-1. Read the qualifications alongside the method list, including the ASTM E23 lateral-expansion exclusion.[3]
- LMATS Sydney — Site 21094, NSW: covers prepared metallic and welded specimens under AS 1544.2, ASTM A370, ASTM E23, ISO 148-1 and AS 2205.7.1. Use Sydney’s own entry rather than transferring Melbourne’s coverage.[4]
- Victorian Testing and Inspection Services, Melbourne — Site 18865, Victoria: covers prepared metallic and welded specimens. Match the required method to its steel Charpy entry; its separate ISO 179-1 plastics/composites entry is not steel-testing coverage.[5]
LMATS Melbourne and Sydney share accreditation number 15840, but have different site scopes.[3][4] Accreditation coverage does not itself mean the laboratory has accepted a particular order; obtain agreement to the intended work.[3][4][5]
Check the temperature range, not just the coldest point
The NATA temperature listings checked on 19 November 2026 are:
- LMATS Melbourne Charpy testing: ambient down to −70°C, and separately at −196°C.[3]
- LMATS Sydney Charpy V-notch impact testing: ambient down to −80°C, and separately at −196°C.[4]
- Victorian Testing and Inspection Services, Melbourne Charpy testing: −70°C to 30°C, and separately at −196°C.[5]
The separate −196°C entry does not establish coverage across the gap between the continuous range’s lower limit and −196°C.[3][4][5]
For example, −75°C falls within LMATS Sydney’s stated range but outside the continuous ranges listed for LMATS Melbourne and Victorian Testing and Inspection Services. Testing at −100°C is not established by these entries, despite each separately listing −196°C.[3][4][5]
Do not substitute a covered temperature merely to fit a laboratory’s scope. Refer a proposed change to the party responsible for the purchase specification, and recheck the selected site’s listing before issuing the request.
Check each additional measurement
Charpy testing records energy absorbed during fracture of a notched specimen.[1][2] Lateral expansion and fracture-surface assessments are separate outputs, so check each requested measurement rather than relying on “Charpy” appearing in the scope.[2][3][4][5]
LMATS describes shear percentage as a visual assessment of the ductile or brittle portions of the fracture surface, and says both shear percentage and lateral expansion are measured on fractured V-notch specimens.[2] The site scopes distinguish their determinations:
- LMATS Melbourne: lists V-notch impact value and lateral expansion, subject to its methods and temperature limits, but explicitly excludes lateral expansion under ASTM E23.[3]
- LMATS Sydney: its ordinary metal-product Charpy entry lists V-notch impact value; lateral expansion and fracture-appearance assessment are not listed in that entry.[4]
- Victorian Testing and Inspection Services, Melbourne: lists impact value, lateral expansion and fracture appearance for prepared metallic and welded specimens, subject to its standards and temperature limits.[5]
Melbourne’s exclusion means an ASTM E23 lateral-expansion result is outside that published site scope, even though “ASTM E23” and “lateral expansion” both appear in the entry.[3] Use the specification’s exact output terminology and agree proposed substitutions between “shear percentage” and “fracture appearance” rather than assuming the labels are interchangeable.[2][5]
Build the laboratory request
Use the following as an ordering checklist. Keep each instruction’s status visible: specification-controlled, suggested traceability, optional or unresolved.
Governing documents — specification-controlled
Purchase specification and revision: [ ]. Material standard or welding code: [ ]. Acceptance clause and requirements: [ ]. Agreed changes and written authority: [ ]. Include averaging, individual minima and retest conditions where the governing documents supply them.[2]Material identity — suggested traceability
Order reference: [ ]. Steel grade: [ ]. Heat/cast number: [ ]. Product form and thickness: [ ]. Sample identifiers and corresponding material records: [ ].Specimen instructions — specification-controlled; unresolved where open
Parent metal or welded test piece: [ ]. Notch type: [ ]. Agreed dimensions: [ ]. Extraction location and orientation: [ ]. Supporting clause or drawing: [ ]. Open items and responsible person: [ ].[2][3]Method and temperature — specification-controlled
Test method and applicable edition: [ ]. Test temperature: [ ]. Governing reference: [ ].[2][3][4]Required and optional outputs
Impact-energy results and acceptance reference: [ ]. Additional specification-required measurements and clauses: [ ]. Optional outputs: [ ]. Requested reporting detail: [agree expressly].[2][3][5]Selected site and exceptions
Laboratory and site identifier: [ ]. Scope checks: specimen category [ ]; method [ ]; temperature [ ]; measurements [ ]; exclusions [ ]. Exceptions and agreed resolution: [ ]. Laboratory confirmation of intended work: [written reference].[3][4][5]
Resolve open instructions and scope exceptions before authorising specimen preparation. A published scope describes covered activities and limitations, not acceptance of this particular request.[3][4][5]
Check the report against the order
Reconcile the report with the agreed request before using the results to demonstrate compliance. This is a buyer’s checking tool, not a list of universally mandatory report fields.[2][3][4][5]
- Identity: match the material and sample identifiers to the request and confirm the specimen category: parent metal or welded test piece.[3][4][5]
- Method and specimen: check the governing specification, test method, notch type, extraction location, orientation and agreed dimensions.[2]
- Temperature and measurements: reconcile the test temperature and requested outputs with the order and the selected site’s scope.[3][4][5]
- Acceptance: compare absorbed impact energy with the applicable specification’s compliance criteria, and additional measurements with their ordered requirements.[2]
- Exceptions: revisit scope exclusions, including LMATS Melbourne’s exclusion of ASTM E23 lateral expansion.[3]
Ask the laboratory to include uncertainty, actual measured temperature, striker radius, specimen-by-specimen values, photographs or conformity statements when required by the specification or expressly agreed.[2][3][4][5]
Record whether the report matches the order, needs clarification or missing information, or differs from an agreed requirement. Refer unresolved technical questions to the laboratory and the party responsible for the specification before deciding how to proceed.
References
- Impact testing | School of Materials Science and Engineering – UNSW Sydney (unsw.edu.au)
- Charpy Impact Tests – LMATS (lmats.com.au)
- LMATS Melbourne Laboratory – Accredited Organisation (Site No. 17127) – NATA (nata.com.au, 2008)
- LMATS Sydney Laboratory – Accredited Organisation (Site No. 21094) – NATA (nata.com.au, 2012)
- Victorian Testing and Inspection Services – Melbourne Laboratory – Accredited Organisation (Site No. 18865) – NATA (nata.com.au, 2010)