HROUS

Ash Content Testing: Requirements for US Resin Buyers

Advertisement

Start with a comparison-ready test order

Before comparing ash results from two resin lots, record specimen identity and sampling, and agree with the laboratory on method, procedure, conditioning, reporting basis and repeats. Separate the method’s scope constraints from recommended purchasing controls: ASTM’s public scope and Intertek’s generic test description (background only, not a verified US testing option) do not establish a mandatory test-order checklist.[1][2]

Advertisement
Closeup of burning paper in a glass container, top view, showcasing flames.
  • Method scope and procedure: If using ASTM D5630-22, have the laboratory confirm material suitability and specify Procedure A or B, specimen mass and form.[2]
  • Recommended traceability controls: Record sample identifiers, their connection to each lot, how samples were collected and the reference material you will retain.
  • Recommended reporting agreement: Specify preparation and conditioning, percentage-ash reporting basis, repeat count and whether individual results accompany the average.
  • Separate analytical request: Specify additional residue analysis separately from the ash measurement; Intertek’s description already includes optical examination.[1][2]

Keep testing with a qualified laboratory. The comparison concerns measured residual solids under agreed conditions, not proof of filler identity: D5630 quantifies residue but does not identify its individual chemical components.[2]

Intertek’s testing description is used here as background only, not as a verified US testing option.[1]

Advertisement

Label specimens and retain a lot reference

Give each submitted specimen its own identifier and an explicit link to its supplier lot. Treat the following as traceability recommendations, not prescribed label fields:

  • Sample identity: Record the buyer sample ID, supplier or producer, resin grade or description, supplier lot number and submitted sample form.
  • Relationship between specimens: State whether they come from different lots, separate collections within one lot or splits of the same collected material.
  • Sampling history: Document who collected the material, when and where it was collected, whether increments were combined and any preparation before submission.
  • Retained reference: Keep clearly linked reference material. Record its identifier, storage location and conditions, and set a retention arrangement.

For example, link the specimen ID to the supplier lot and to a separate retained-reference ID. Keep that mapping with the order and resulting report so later questions can be tied to the submitted material.

Neither ASTM’s public scope nor Intertek’s description establishes a required label format, lot-sampling plan, chain-of-custody form or retained-reference period; nor do they provide a sampling plan establishing whole-lot representativeness.[1][2] A clear label identifies the specimen—it should not be treated as proof that the specimen represents the entire lot.

Advertisement

Confirm the method fits the material

ASTM lists D5630-22 as the active standard for ash content in plastics.[2] Before requesting it for both lots, have the laboratory check the material against its published scope:

  • Measurement: Destructive ashing to determine inorganic content at ash levels of 0.01% or higher.[2]
  • Material stability: Coverage is limited to materials, including glass, stable at 900°C.[2]
  • Exclusions: Fluorinated polymers and polymers containing halogenated components are not included in the procedures.[2]

The 900°C statement is a material-suitability boundary, not a furnace-setting instruction for the buyer.[2] Give the laboratory the available resin and composition information and request confirmation of applicability.

For unknown samples, or where fusion of the inorganic portions may be a concern, ASTM recommends D2584.[2] Resolve that method-selection question before ordering matching tests. The objective is an applicable method for both specimens, not merely the same standard number printed on two reports.

Advertisement

Agree on procedure, preparation and conditioning

Once suitability is established, request the complete standard designation and edition, selected procedure and any deviations on the order and report. These are recommended comparison controls, rather than order-field requirements established by ASTM’s public scope.[2]

The procedure matters: Procedure A uses 5–50 g specimens; Procedure B uses 2–10 g specimens. ASTM also recommends powder or pellet form for more efficient ashing.[2]

For each lot, agree on and record:

  • Specimen form and mass per determination.
  • Preparation before testing, including any conditioning or drying.
  • The specimen’s condition when its original mass is established—for example, as received or after an agreed drying step.
  • Any differences between the preparation used for the two lots.
Advertisement

Agree with the laboratory on conditioning duration, humidity, temperature and any dry-basis requirement rather than assuming a shared standard designation settles these details.[1][2]

Intertek describes a typical 6 g sample divided among three crucibles containing 2 g each.[1] That per-crucible mass falls within Procedure B’s range, but the numerical match does not establish that Intertek’s generic arrangement implements Procedure B.[1][2]

Intertek cautions that its description is generic and directs readers to obtain the relevant standards.[1] Use the applicable standard—not a provider summary—as the laboratory’s operating specification.

Specify reporting basis, repeats and residue observations

Request a defined percentage, not simply a number labeled “ash.” Intertek calculates percentage ash = ash mass ÷ original sample mass × 100.[1] The order should make clear what result is expected and how it will be presented.

Advertisement
  • Define the denominator. Ask what “original sample mass” represents after any agreed conditioning. Specify as-received reporting or another expressly defined basis as a comparison agreement, not an assumed method requirement.
  • Set the repeat count. Agree on the number of determinations before testing and request individual results plus the average. Intertek typically averages three crucibles; that is a provider practice, not a universal three-repeat requirement.[1]
  • Separate observations from mass measurement. Request residue observations as a distinct report item. Intertek describes magnified optical examination classifying residue as glass, mineral or a combination.[1]
  • Define additional reporting requests. If needed, agree on uncertainty statements, residue photographs and a particular report format rather than assuming they are included.

The cited pages do not establish a repeat-selection rule or mandatory requirements for individual-result disclosure, reporting basis, uncertainty statements, photographs or report format.[1][2] Record the agreed choices so the second lot can be ordered and reported on the same basis.

Advertisement

Resolve differences before judging the lots

Before interpreting a numerical difference, put the reports side by side. For each field below, mark the entries aligned, different or not documented:

  • Traceability: Specimen identity, link to the supplier lot and sampling record.
  • Method: Standard edition, procedure and reported deviations.
  • Specimen: Form and mass per determination.
  • Preparation: Preparation and conditioning used.
  • Results: Reporting basis, repeat count and whether the reported value is an average.
  • Residue examination: What was observed and whether additional analysis was performed.

This is a recommended buyer review tool, not an ASTM-defined acceptance system. ASTM’s public scope and Intertek’s description provide neither a formal discrepancy-resolution process nor a universal acceptable lot-to-lot difference.[1][2]

Advertisement

A shared D5630 citation does not settle every comparison question: ASTM distinguishes procedures with different specimen-mass ranges.[2] Likewise, a reported average should be distinguished from an individual determination; Intertek’s typical result averages three crucibles.[1]

For missing details, request clarification or an amended report. Do not treat an absent recommended buyer field as automatic invalidation. Where procedures differ materially, ask the qualified laboratory whether the results can be reconciled or whether testing under a common agreed procedure is needed.

As a purchasing control, keep the numerical lot judgment pending while a material comparison question remains unresolved. This is not an automatic reason to accept or reject either lot.

Advertisement

Distinguish ash percentage from filler identity

Even with aligned procedures, ash percentage measures residual solids, not chemical identity. ASTM says residue may include antiblock materials, fillers, reinforcements, catalyst residues and colorants; D5630 does not qualitatively identify the individual chemical components.[2]

A higher ash percentage therefore indicates more measured residue under the agreed conditions—not, by itself, more of a named filler or evidence of supplier substitution. Matching ash percentages likewise do not establish identical composition.[2]

ASTM describes consistent filler-content results for a specific filler in a specific resin, but cautions that the method may not provide absolute filler content in every case, including calcium-carbonate-, nanoclay- and carbon-black-filled polymers.[2] Intertek says carbon fiber and carbon black burn off during testing, so ash testing cannot determine their percentages.[1]

Advertisement

Do not turn a residue interpretation into an acceptance limit. Intertek considers residue filler unless it is below 1%, and typically attributes residue below 1% to additives that did not burn off.[1] ASTM’s coverage begins at 0.01% ash.[2] These figures address different questions: Intertek’s generic interpretation of residue versus ASTM’s measurement scope. Neither supplies a universal lot-acceptance threshold.[1][2]

If the question is which mineral is present, Intertek describes FTIR analysis of the residue as a possible identification aid. It also says determining individual filler percentages in materials containing multiple fillers requires additional procedures.[1] Specify that composition question separately from the ash-content measurement.

Choose the next step

  • Compare aligned results. Use an existing, agreed purchase specification rather than a limit inferred from the test method. Alignment supports comparison; it does not establish lot equivalence or create an acceptance threshold.[1][2]
  • Clarify or retest mismatched results. Ask the laboratory to resolve missing information and procedural differences. If reconciliation is not possible, agree on a common testing plan before retesting.
  • Request further analysis for composition questions. D5630 measures residual solids rather than identifying their chemical components.[2] Have the laboratory select follow-up work for the specific question; residue FTIR may aid mineral identification, while individual percentages in multiple-filler materials require additional procedures.[1]

Before sending the order, confirm material suitability, link specimens to their lots, agree on procedure and conditioning, and define reporting basis and repeats. Keep those comparison controls distinct from the method’s scope—and keep filler identification distinct from the ash percentage.

References

  1. Ash Content ASTM D2584, D5630, ISO 3451 (intertek.com)