Sound Level Meter Calibrator: Choice for UK Survey Teams
Choose a sound level meter calibrator by matching its microphone interface, reference output, class and calibration evidence to your documented survey procedure—not simply to the meter’s brand. Cirrus specifies defined microphone interfaces and adaptors rather than brand-wide compatibility.[1][2][3]

Use this purchasing checklist to separate requirements from preferences:
- Required by your method: identify the microphone and supported coupler; establish the reference level, frequency, calibrator class, accepted standards edition and laboratory evidence.
- Optional capability: keep extra output settings or a preferred certificate route separate unless the procedure requires them.
- Unresolved: record any missing compatibility or evidence decision before accepting a candidate.
1. Identify the microphone and survey procedure
Gather the meter instructions for the configuration being used, microphone identification and instructions, the survey procedure with its revision and referenced standards, and existing calibration documentation. This is a suggested purchasing checklist, not a prescribed document list.
Build a requirements worksheet with four entries. For each, record the requirement, controlling document and clause, candidate specification and unresolved issue:
- Microphone interface: capsule diameter, coupler fit and any adaptor.
- Reference output: required level and frequency.
- Class and edition: required calibrator class and accepted standards edition.
- Laboratory evidence: required certificate and traceability.
Leave required values blank until they can be established from the relevant documentation. Mark each condition as required by the procedure or optional preference, retaining the supporting clause. A product description is evidence of the candidate’s specifications, not a substitute for the survey method.
2. Match the capsule, coupler and adaptor
Identify the installed microphone model and its documented capsule diameter; do not infer fit from the meter housing or brand. Cirrus specifies microphone interfaces, not blanket compatibility with every microphone fitted to a particular meter.[1][2]
The single-level CR514 and CR515 and dual-level CR516 and CR517 accept a standard 1/2-inch microphone to IEC 1094-4. Both product families identify the QD:7 adaptor for 1/4-inch capsules.[1][2]
- Documented standard 1/2-inch interface: compare the microphone specification with the calibrator’s stated direct-fit interface.[1][2]
- Documented 1/4-inch capsule: specify the QD:7 adaptor and check the proposed microphone–adaptor combination against the equipment documentation.[1][2]
- Other or unknown interface: ask Cirrus for compatibility evidence for the capsule diameter before accepting the fit.[1][2]
Treat diameter as a screening check. Use the microphone and calibrator instructions to support the exact combination before ordering. Record the microphone model, diameter, calibrator interface and adaptor designation—or documented direct fit—in the purchasing specification.
3. Choose the required reference output
Copy the required reference level and frequency from the survey procedure and instrument instructions. Compare both with the candidate’s published output, rather than choosing by the number of settings available.
- Single-level: Cirrus publishes 94 dB ±0.2 dB at 1 kHz ±1%. Its stated reference conditions are 23°C, 101.3 kPa and 65% relative humidity.[1]
- Dual-level. Cirrus lists selectable 94 dB and 114 dB outputs at 1 kHz. Check the certificate or model specifications for the tolerances at the output you will use.[2]
Cirrus describes ±0.2 dB as typical for both levels. If the survey procedure requires a guaranteed tolerance at 94 dB or 114 dB, request written confirmation for the selected level and a certificate identifying the instrument.[2]
Separate output tolerance from check acceptance. The published ±0.2 dB describes the calibrator output; it does not establish a permitted deviation for the survey’s field check.[1][2] Record the acceptance criterion from the applicable procedure or instrument instructions separately.
4. Match calibrator class and standards edition
Cirrus describes Class 1 as offering tighter tolerances and Class 2 as suitable for general field checks. Use the controlling survey procedure—not those descriptions—to decide the required class.[1][3]
The four Cirrus models separate as follows:
- CR514: single-level; IEC 60942:2017 Class 2.[1]
- CR515: single-level; IEC 60942:2017 Class 1.[1]
- CR516: dual-level; IEC 60942:2017 Class 2.[2]
- CR517: dual-level; IEC 60942:2017 Class 1.[2]
Keep the meter’s class separate from the calibrator’s class. Cirrus’s service page discusses distinct specifications for the instruments and cites BS EN 60942:2003 for calibrators, while the product pages specify IEC 60942:2017.[1][2][3]
Edition acceptance remains unresolved: ask the person responsible for the survey procedure to confirm whether the proposed IEC 60942:2017 calibrator is accepted where the procedure specifies BS EN 60942:2003.[1][2][3] A newer date alone does not settle the match.
Before marking a candidate as meeting the specification, document the required class and edition and the basis for accepting the proposed model against them. Keep an unresolved edition question visible rather than treating it as a match.
5. Select laboratory evidence separately
A calibrator provides a stable reference signal for checks before and after use. Those field checks are separate from laboratory calibration, which Cirrus describes as acoustic and electronic testing followed by a calibration certificate.[1][2][3]
Cirrus offers standard traceable and UKAS-accredited calibration as separate options. It identifies its UKAS laboratory as No. 10148 and states that it meets ISO 17025.[3] Select the evidence route against the documented method:
- Accredited evidence specified: check the proposed laboratory’s applicable accredited scope and certificate against that requirement.
- Another traceability requirement specified: compare its wording with the proposed service and certificate, rather than relying on the service label.
- Requirement unclear: resolve it with the person responsible for the survey procedure before selecting the certificate option.
Cirrus says UKAS-accredited calibration may be particularly relevant where the credibility and reliability of evidence are challenged.[3] That description is not a reason to assume accreditation is mandatory for every survey.
Request confirmation that the proposed certificate identifies the relevant instrument and supports the evidence the method requires. Owning a calibrator alone does not establish survey compliance: field-check capability and laboratory evidence address different parts of the measurement process.[1][2][3]
6. Prepare the field-check record
Set the acceptance criteria before the survey. Cirrus describes before-and-after-use checks using a stable reference signal; its product and service pages do not prescribe exact record fields, permitted drift or corrective-action rules.[1][2][3]
Suggested check sequence:
- Identify the meter, microphone and calibrator combination.
- Follow the equipment instructions and documented survey procedure.
- Record the required pre-use result and, after measurement, the post-use result.
- Compare results with the procedure’s acceptance criteria and record the outcome and action taken.
A suggested record includes the survey reference, date, time, operator, equipment identifiers, reference setting, pre-check and post-check readings, acceptance criterion, procedure reference, outcome and corrective action. These are recommended fields, not a prescribed format.
Use the documented procedure to decide acceptance and corrective action. Do not insert an assumed drift allowance or automatic adjustment rule into the template.
7. Link instruments and dated checks in a register
Give each equipment combination a register reference and link its survey check records. Record the following details in the register:
- Combination reference: record the equipment combination ID.
- Meter: record the model and serial number.
- Microphone: record the model, serial number and capsule diameter.
- Calibrator: record the model and serial number.
- Coupler or adaptor: record the designation or documented direct-fit interface.
- Laboratory evidence: record the instrument covered, certificate reference, calibration date and whether the calibration is standard traceable or UKAS-accredited.
- Procedure: record the document reference and revision.
- Field checks: record the survey references and links to dated check records.
Populate interface details from the equipment documentation, including QD:7 where used.[1][2] Link each certificate to the instrument it covers. Cirrus supplies a certificate after laboratory calibration and offers both traceable and UKAS-accredited options.[3]
If a microphone, calibrator or adaptor changes, preserve which combination each survey used. Add a next-review or recalibration date where the documented procedure or calibration evidence supplies its basis, and record that basis alongside the date.
8. Finalise the purchase specification
Bring the worksheet and register together into a specification. Beside each claimed match, retain the document title, revision and relevant page or clause:
- Fit: microphone model and diameter; calibrator interface; exact adaptor or supported direct fit.
- Output: required level and frequency alongside the proposed model’s published values.
- Class and edition: method requirement, candidate declaration and documented acceptance basis.
- Evidence: certificate route and instruments to be covered.
- Status: required condition, optional capability or unresolved evidence.
Pause acceptance for an unidentified microphone, unsupported interface, missing output evidence, unresolved class or edition match, or unclear certificate requirement. Extra output settings or a preferred certificate route should not obscure a missing mandatory fit.
References
- Acoustic Calibrator | Cirrus Research (cirrusresearch.com)
- Dual-level Acoustic Calibrator | Cirrus Research (cirrusresearch.com)
- Acoustic Calibration Services | Cirrus Research (cirrusresearch.com)