Before signing off a light booth for color matching, buyer and printer should agree on the samples, acceptance lighting, usable comparison area, surroundings and maintenance evidence. Separate conditions required for the agreed assessment from conditional checks and optional accessories. GTI ties consistent cross-booth comparisons to matching surroundings and source performance. [1]

Close-up of a DJ mixing music with equipment and colorful lights in a nightclub setting.
Advertisement

Start with the samples and acceptance task

Use a shared viewing-condition sheet to settle these points before choosing equipment:

  • Required for the agreed assessment: Identify the physical reference, proof and production sample, substrate, governing company or industry practice, and acceptance conditions. GTI says the governing practice should take precedence. [1]
  • Conditional on the sample or end use: Identify optical brighteners, additional illuminants, UV checks and any special backing or sample holder. GTI connects fluorescent behavior to the viewing source’s UV content and recommends different inserts for particular samples. [1]
  • Optional convenience: Keep accessories separate from acceptance criteria. JUST’s booth literature lists holders, stands, cabinets and control software as optional equipment. [3]

Plan for the largest proof and production sample that will be viewed side by side. Record the conditions at both sites and the position each sample and observer will occupy. [1][3]

Advertisement

Choose acceptance illuminants and record UV

GTI describes D50 as a graphic-arts viewing condition. Agree the acceptance illuminant with the printer and record any additional illuminant separately. JUST describes equipment that can switch between D50 and D65. Test the setting selected for the job at both locations. [1][2]

For each assessment, record:

  • Illuminant identity and nominal color temperature: Identify the selected source setting at both locations. [1][2]
  • UV state: State whether UV is included or excluded. [1][2]
  • Decision role: Mark whether the condition controls acceptance or provides an additional end-use check. [1]

Resolve UV when optical brighteners are present or possible. GTI says daylight-source UV energy is necessary for these samples, and a separate UV source can reveal fluorescence. Treat that check as additional information, not a substitute for agreeing on the daylight source’s UV condition. [1]

Advertisement

Keep visual approval separate from instrument color measurement. GTI warns that a fluorescent sample measured with UV excluded can produce data that disagree with visual evaluation under UV-containing light. Record the measurement’s UV condition separately when instrument results accompany the visual judgment. [1]

Extra modes are capabilities, not mandatory tests. JUST reports that specified DLS proofing systems switch between D50 and D65 and allow UV-A to be enabled or disabled under either illuminant. Use those controls to reproduce the agreed condition rather than making every setting an acceptance condition. [2]

Resolve category, surrounds and light levels together

Record the standard and edition named in the order. ISO 3664:2025 puts print conditions P1 and P3 under critical comparison and P2 and P4 under practical appraisal, including routine inspection. Agree which task the buyer is signing off on. Then record the selected condition, illuminant, UV state, illuminance and uniformity criteria, surround and sample layout for that condition.

GTI gives practical guidance on controlling the surround and keeping visual conditions consistent. Ask the supplier for the test report for the actual booth model and record which lamp, setting and edition it covers. Agree the same criteria and measurement method at the buyer and printer sites. [1][2][3]

Advertisement

Verify the usable area with both samples in place

Measure the area needed to place the largest proof and production sample side by side. Include room to observe the surfaces in the chosen position. [2][3]

Compare the sample layout with the equipment’s specified illuminated viewing area and ask for a test with the largest pair. JUST describes viewing areas and cabinet dimensions separately. [2][3]

Measure or request measurements at the points the samples actually occupy, then check those readings against the uniformity criteria for the specified condition. Use the same approach at both sites.

Accept the physical layout once both agreed samples fit within the illuminated area and the measurements meet the job’s criteria across that space.

Advertisement

Control surroundings and sample presentation

Record the surround, sample position and the approach to reflections and light from the surrounding room. GTI describes controlling the booth environment to make viewing more consistent. [1]

Document inserts as exceptions. GTI recommends white inserts for extremely light or pastel samples and black inserts for very dark or high-gloss samples. If an insert is selected, include it in the shared setup so neither location silently changes the comparison environment. [1]

GTI says sample aids should match the booth color, avoid casting shadows, be removable and support predefined sample angles. Record the chosen angle so buyer and printer can reproduce the presentation. [1] Select holders, stands and interior linings only where they support the agreed setup; their availability does not make them universal requirements. [1][3]

Advertisement

Check source documentation and compliance claims

A D50 label or nominal color temperature alone is insufficient evidence of compliance. GTI describes lamps, reflectors and diffusers as parts of the rated system and warns that substituting another manufacturer’s lamps can invalidate its stated ASTM and CIE ratings. [1]

Request documentation tied to the equipment being accepted:

  • Equipment identity: Exact booth and lamp or LED model, plus the manufacturer’s original-equipment replacement specification. [1][2][3]
  • Source configuration: Illuminant identities, UV state, and switching or dimming controls. [1][2]
  • Performance evidence: Claimed standard and version, technical specifications, CRI where used, CIE Publication 51 visible/UV rating, and supporting test documentation. [1][2][3]

Keep quality figures in context. GTI states a minimum CRI of 90 for color assessment while recommending replacement D50/D65 lamps with CRI 92 or better and CIE Publication 51 B/C or better. These are GTI’s criteria, not a complete, independently verified acceptance test. [1]

Review the exact condition and standard edition named in the supplier’s claims. Ask for the test evidence for the installed booth and its approved replacement sources. Record which settings and documents the buyer and printer have agreed to use. [1][2][3]

Advertisement

Record maintenance that preserves the condition

Keep a maintenance log alongside the source documentation:

  • Source history: Operating hours where available, replacement dates and exact installed source identity. [1][3]
  • Surround condition: Cleaning or stain treatment and panel or liner replacement. [1]
  • Service evidence: Recalibration performed and matching-process reports where supported. [3]

JUST’s literature describes operating-hour displays, lamp-change alerts and matching-process reports; verify which functions the selected model includes. [3] JUST also publishes a lifespan comparison of 50,000 hours for LED versus 2,500 hours for fluorescent lamps. Treat this as a vendor lifespan claim, not a guaranteed color-performance period or universal replacement interval. [2]

Record the approved replacement specification rather than accepting a nominally similar lamp: GTI warns that unapproved replacements can compromise stated ASTM/CIE ratings. Its cleaning guidance allows mild soap and water for small stains and replacement components or inserts for stubborn contamination. [1]

Schedule maintenance from the operating instructions for the actual booth. Record source identity, operating hours and any recalibration after a change. Use those records when repeating a viewing comparison. [1][2][3]

Advertisement

Use a joint handoff checklist

For each item, record the agreed requirement, buyer-site evidence, printer-site evidence and unresolved action, including who will resolve it:

  • Samples and substrate: Identify the reference, proof, production sample and optical-brightener status. [1]
  • Acceptance lighting: List acceptance illuminants and the UV state for each; separate additional checks. [1][2]
  • Viewing condition: Name the category, claimed standard/version, surround, backing, finish, sample presentation and illumination criteria. [1]
  • Usable area: Attach illuminated-area dimensions and evidence that the largest comparison pair fits. [2]
  • Source evidence: Attach source identity, replacement specification, quality ratings and supporting performance documentation. [1][2]
  • Maintenance: Include operating hours, replacement history, cleaning or panel changes and recalibration performed. [1][3]
  • Optional features: Mark accessories and additional controls as selected or unused, separately from acceptance criteria. [2][3]

Recommended hold rule: Leave sign-off open while a required field remains unresolved, the comparison pair exceeds the documented illuminated area, or a compliance claim lacks the evidence both parties agreed to require.

This handoff accepts the viewing setup, not an individual production sample. Keep instrument results separate, particularly where UV-sensitive samples could produce disagreement between visual judgments and measurements made without UV. [1]

References

  1. GTI Graphic Technology Inc.- FAQs (gtilite.com)
  2. LED-based color matching | JUST Normlicht (just-normlicht.com)
  3. VIEWING BOOTHS “COLOR VIEWING LIGHT“ – ABSTRACT (just-normlicht.com)